Your Location:Home > PRODUCTS>Paper and Packaging Testing Equipment>Paper Tester

XHV-43B Diaper Permeability Tester

Product Description of XHV-43B Diaper Permeability Tester

Diapers Permeability Tester Used to test the permeability performance of diapers, such as absorption speed, rewet, leakage.


Test Standards of XHV-43B Diaper Permeability Tester


GB/T 28004.1-2021 Diapers Part 1Infant Diapers

GB/T 28004.2-2021 Diapers Part 2Adult Diapers


Product Features of XHV-43B Diaper Permeability Tester

1. The test solution used for testing is controlled by a peristaltic pump to ensure the stability and repeatability of the addition, with an accuracy of ± 1%.

2. The heating method of the test solution (physiological saline) adopts a water bath heating method and is stored in a glass jar, without any impact on the performance of the test solution.

3. Color touch screen control, English menu, man-machine dialogue mode, convenient to operation.

4. 5 positions, can be set and test liquid filling volume and flow rate of each position separately.

5. 5 independent electrodes and pumps, can test different types of samples including adults and baby.

6. Diaper Permeability Testing Equipment: Automatically fill liquid, test, weigh

7. Platinum electrode, good induction and positioning automatically.

8. Adopting stepping motor and high-precision ball screw drive, accurate stroke.

9. Data processing automatically, including average, standard deviation, and coefficient of variation.

10. Thermal printer,for printing of test results quickly.


Technical Parameter of XHV-43B Diaper Permeability Tester

Standard Liquid Module

 

Baby

W

(80±1)mmM1

(85±1)mmM2

(95±1)mmM3

L

(100±1)mmM1

(108±1)mmM2

(125±1)mmM3

Adult

W

(70±1)mmM1

(95±1)mmM2

/

L

(170±1)mmM1

(170±1)mmM2

/

 

Standard Pressure Module

 

Baby

W

(80±1)mmY1

(85±1)mmY2

(95±1)mmY3

L

(100±1)mmY1

(108±1)mmY2

(125±1)mmY3

Adult

W

(70±1)mmY1

(95±1)mmY2

/

L

(170±1)mmY1

(170±1)mmY2

/

 

Sample Base

 

Baby

U- Shaped Sample Base

W

(122±1)mmB1

(135±1)mmB2

(152±1)mmB3

L

(125±1)mmB1

(136±1)mmB2

(154±1)mmB3

Adult

ARC Sample Base

319mm×200mm 


Test Position

5

Control Mode

Touch Screen Control

Range of Timer

0.00 - 9999.99 s

Liquid Addition Device

Deviation of liquid addtion volume ±2mL

Dosing Flow Rate

Baby: (480±5)ml/min

Adult: (720±5)ml/min

Pressurize Pressure

2.0±0.2 KPa, 4.0±0.2 KPa

Liquid Heating Range

RT+5℃-50℃

Dimension

1220mm×220mm×500mm

Power Supply

AC220V 50Hz 


Relative Products of XHV-43B Diaper Permeability Tester

Hot lines:

+86-531-67880131

Address:No. 2 East Street Shengchan Road Jinan City Shandong China

Jinan Xinghua Instruments Co.,Ltd. All Rights Reserved